Look up a term or check a concise planning note. For a complete lesson, use the subject index.

Glossary

Plain-language definitions with technical precision

Useful for beginners, but written so experienced users do not have to tolerate oversimplified explanations. Terms are intentionally connected to how they are used in troubleshooting and review.

m/z

Mass-to-charge ratio used to label ion signals.

Ionization

Formation of ions from atoms or molecules. The resulting ion may have a different composition or charge state from the original analyte.

Mass Analyzer

Subsystem that separates ions by their motion behavior linked to m/z.

Detector

Hardware that converts ion behavior into electrical signal, through ion impact or induced image current depending on the instrument.

Adduct

An ion species formed by association (for example protonated, sodiated, or ammoniated molecules) that shifts observed m/z and may alter fragmentation behavior.

ppm Error

Parts-per-million deviation between observed and expected m/z. Useful for mass accuracy monitoring, but not sufficient by itself to confirm identity.

Mass Error

Difference between measured and expected mass value.

Residual

Remaining fit error after calibration model correction.

LOD / LOQ

Limits of detection and quantitation describing the lowest detectable or reliably quantifiable signal under defined conditions and criteria.

Resolution / Resolving Power

A measure of separating nearby peaks. Report the criterion and m/z; the FWHM convention uses R = (m/z) / peak width. High resolving power alone does not guarantee low mass error.

Dynamic Range

Signal range where response remains useful and interpretable.

Baseline

Background signal level under peaks.

Accuracy vs Precision

Accuracy concerns agreement with a reference; precision concerns agreement among repeated measurements under stated conditions. Repeatability is one set of conditions. A tightly grouped set can still be systematically offset.

Calibration

Mass-axis calibration aligns measured m/z positions with reference values. Quantitative calibration separately relates response to concentration.

Tuning

Adjusting operating parameters for stable and useful signal behavior.

Matrix Effect

Effects of sample components on analyte response, which may involve sample introduction, ionization, transmission or other processes. Ion suppression in ESI is one example, not the entire definition.

Carryover

Signal from previous samples contaminating later runs.

Internal Standard

A selected substance or element added at a defined amount to help track response variation. Correction is limited to processes after its addition and to effects it follows sufficiently like the analyte; it cannot repair every loss or interference.

Lock Mass / Reference Mass

A known ion used to monitor or correct mass accuracy during acquisition. It improves stability tracking but does not fix all causes of poor spectral quality.

Duty Cycle

The effective sampling time pattern of the instrument across targets or scan events. Duty cycle affects points per peak, sensitivity, and temporal resolution.

Profile vs Centroid Data

Profile data samples signal across the m/z peak shape; centroid data represents detected peaks by estimated positions and intensities. Processing choices affect which features remain and the values reported.

Isotopic Pattern

The expected distribution of isotope-related peaks for an ion. Useful for confirmation, charge assessment, and detecting overlaps or annotation errors.

Selectivity

The ability of a method to distinguish an analyte from interferences under stated conditions. Selectivity is built through sample prep, separation, acquisition, and review criteria together.

System Suitability

Checks that provide evidence the system meets specified criteria for the intended analysis. Passing does not guarantee every unknown sample is valid.

Integration / Reintegration

Software estimation of peak area or height, sometimes adjusted manually. Any manual reintegration should be rule-based, documented, and reviewable.

Drift

Gradual change in instrument behavior over time.

Saturation

Detector regime where increased ion input no longer produces proportional response.

Techniques

Technique-specific entry points with practical pitfalls

Short technique orientations. These are not separate completed course tracks.

GC-MS

Volatile analytes, EI spectra, library matching, retention behavior, and contamination/carryover patterns that mimic real signal.

LC-MS

Liquid-phase separation, electrospray behavior, adduct formation, matrix effects, and batch-to-batch reproducibility.

MALDI / TOF

Matrix selection, crystal quality, spot preparation, pulse timing, and spectrum variability caused by sample presentation.

ICP-MS

Elemental analysis, isotopes, plasma tuning, interferences, internal standards, and washout-driven memory effects.

How to Choose a Technique (High Level)

Start with the question and sample constraints: target type, volatility, polarity, expected concentration range, required selectivity, throughput, and what kind of evidence the final decision requires.

Common Cross-Technique Mistakes

Users often overinterpret single peaks, ignore blanks, confuse tuning with calibration, and change multiple parameters at once. Record the evidence and isolate one hypothesis before changing a method.

Workflows

Sample-to-answer playbooks for common use cases

High-level decision checklists, not protocols. They highlight questions to ask; the instrument method and laboratory SOP supply the actual sequence and acceptance limits.

Small Molecule LC-MS Workflow

Typical path for targeted or semi-targeted analytes in complex matrices.

  • Define analytes, matrix, and reporting requirement
  • Select extraction and internal standard strategy
  • Establish chromatographic separation goals
  • Configure acquisition and review transitions
  • Validate calibration range and QC placement

GC-MS Volatiles Workflow

For volatile/semi-volatile analysis where separation quality and library interpretation both matter.

  • Match sample volatility and cleanup to inlet strategy
  • Track carryover and column bleed separately
  • Use chromatographic context before library matching
  • Evaluate qualifier ions and retention behavior
  • Document confidence and exclusions transparently

ICP-MS Elemental Quant Workflow

Focuses on calibration integrity, interference control, and long-batch stability.

  • Define analyte panel and likely interferences
  • Choose internal standards and correction approach
  • Set calibration and continuing calibration checks
  • Trend drift and washout performance
  • Review outliers against matrix and prep notes

Go / No-Go Criteria at Each Stage

Good workflows define stop points. If blanks fail, washout is poor, or QC trends drift, the right move is often to pause and diagnose, not to continue collecting invalid data.

Communicating Results and Uncertainty

Teach users to report what is measured, how it was confirmed, what thresholds were applied, and what limitations remain. This is where technical quality becomes operational trust.

Method Development

A practical framework for developing robust MS methods

Reference notes for framing a method-development question. These do not replace an experimental plan, validated procedure or technique-specific guidance.

1. Define the Measurement Goal

Start with what decision the data must support, not what the instrument can do.

  • Identification, screening, or quantitation?
  • Required confidence and acceptable uncertainty
  • Matrix complexity and expected interferents
  • Throughput, turnaround, and cost constraints
  • Documentation or regulatory expectations

2. Build a Parameter Screening Plan

Choose a small set of high-impact variables to screen first before fine tuning everything else.

  • Sample prep cleanup and extraction recovery
  • Chromatographic selectivity and peak shape
  • Ionization mode and source stability
  • Acquisition timing, dwell, and cycle time
  • Response normalization and standards

3. Stress-Test for Robustness and Transfer

A method is not complete when it works once. It is complete when it survives expected variability.

  • Operator and day-to-day differences
  • Matrix variation and concentration extremes
  • Instrument drift and maintenance intervals
  • Software processing settings and review rules
  • Clear change control and versioning

When to Use Screening vs Full DOE

Not every lab needs formal DOE for every method, but every lab benefits from disciplined variable control. Interactions can make a structured design more informative than changing one factor at a time.

Define Success Metrics Early

Pick objective metrics before optimization begins: signal stability, mass accuracy, points per peak, carryover threshold, QC recovery, precision, and false positive tolerance.

Data Analysis

Interpretation and processing workflows that stay auditable

Practical review prompts. Follow the linked worked primers for complete examples; other cards are brief reference notes.

Raw File Review Before Processing

Check acquisition metadata, instrument status flags, calibration state, chromatogram quality, and obvious contamination before trusting software output. This catches many problems earlier than peak table review.

Peak Picking and Threshold Choices

Thresholds reduce noise but can also bias low abundance features. Centroiding, smoothing and deisotoping can each change the feature list; compare processing choices against suitable references and raw data.

Blank Subtraction Without Hiding Real Problems

Blank subtraction is useful, but it can conceal contamination trends or unstable systems if applied mechanically. Learn when to subtract, when to annotate, and when to stop the batch.

Building Identification Confidence

Use orthogonal evidence: exact mass (where relevant), isotope patterns, fragments, retention behavior, library score interpretation, and controls. No single metric should carry the full claim.

Quantitation Data Review and Curve Evaluation

Evaluate calibration residuals, weighting assumptions, internal standard behavior, and reintegration decisions using documented criteria rather than visual preference alone.

Traceable Reporting and Auditability

Record processing version, peak integration edits, exclusions, and manual interventions. Auditable review protects both scientific quality and operational credibility.

QA / QC

Quality systems that support reliable MS results

Quality-control planning prompts. Frequencies, limits and required actions come from the applicable method and laboratory procedures.

System Suitability and Startup Checks

Define a short, repeatable startup routine that answers whether the system is ready for real work.

  • Mass axis check and tuning status review
  • Background/noise snapshot and blank response
  • Sensitivity check against expected range
  • Peak shape and retention behavior (if coupled separation)
  • Documented go/no-go criteria

Calibration and QC Monitoring

Build QC placement and acceptance rules that detect drift without forcing constant reruns.

  • Calibration design and weighting rationale
  • Continuing checks and drift thresholds
  • Blank review for contamination and carryover
  • QC trend interpretation over batches
  • Rerun and rejection decision logic

Change Control and Corrective Actions

When methods or processing rules change, preserve comparability through explicit versioning and impact notes.

  • What changed, why, and who approved it
  • Impact on historical comparability
  • Retraining needs and competency checks
  • Deviation documentation with evidence
  • Preventive action after repeated issues

Practical QC Trending (Without Overcomplication)

Trend a small set of meaningful metrics first: response, mass error, retention time, background, and blank carryover. The goal is early detection, not dashboard inflation.

Repeatability vs Reproducibility in Daily Operations

Users often report precision from ideal runs only. State whether replicates vary by run, day, operator, instrument or laboratory; do not call all of these repeatability.

Find a complete lesson

The subject index and search organize all completed lessons and tools in one place. Follow a learning path if you want a sequence.

Read chromatograms in spectral context

This topic now has a full guide. Read read chromatograms in spectral context →

Blanks, controls and carryover

This topic now has a full guide. Read blanks, controls and carryover →

Troubleshoot mass spectrometry

This topic now has a full guide. Read troubleshoot mass spectrometry →